Oct 2026
6 Mins
Guided Surgery Accuracy: Why Does Free Drilling Distance Matter?
Guided Surgery Accuracy: Why Does Free Drilling Distance Matter?
Guided Surgery Accuracy: Why Does Free Drilling Distance Matter?


Dr. Simon Doliveux
DDS, MMSc
In guided implant surgery, the free drilling distance below the sleeve has a significant effect on implant accuracy. Here is what the research shows and what it means for how your surgical guide is designed.
The accuracy of a surgical guide depends on the anatomical and clinical variations of the implant site, but also on an understanding of the geometric properties of the guide itself.
A key aspect of guided surgery accuracy is the drilling distance between the sleeve and the apical end of the osteotomy. This part of the drilling is called “free”: once the implant drill passes the base of the sleeve, it is no longer guided.
Understanding this distance, and taking it into account during implant planning, changes the way the guide itself is designed.
This is what a study led by Dr. Karim El Kholy, co-founder of D2D, set out to highlight in an article published in Clinical Implant Dentistry and Related Research in 2019 [1].
The impact of free drilling distance
In their in vitro study, Dr. El Kholy et al. looked at three variables of static computer-assisted implant surgery (sCAIS):
Sleeve height: the vertical distance between the base of the sleeve and the bone crest.
Drilling distance: the length the implant drill travels from the base of the sleeve without lateral support (14, 16 and 18 mm).
Drilling key: the height of the key that is inserted into the guide sleeve.

Results
This study shows that some choices made when designing the guide play a role in surgical accuracy, while other parameters do not necessarily have the expected impact.
The article showed that sleeve height alone does not significantly change the 3D position of the implant. Likewise, changing implant length alone does not appear to alter the accuracy of guided surgery.
However, drilling distance does appear to affect the accuracy of guided surgery. For example, an 18 mm drilling distance produced a significant deviation of the implant from its planned position, compared with a 14 mm drilling distance [1].

What the article clearly demonstrated is that the distance over which the implant drill is actually guided has a significant influence on implant deviation. The longer the drill is guided laterally, the more accurate the implant position. In other words, the shorter the drilling distance below the sleeve and the greater the key height, the more the drill is truly guided, and the less deviation occurs. Conversely, the longer the unsupported, or “free”, drilling distance, the greater the risk of deviation.
Impact on guide design
The purpose of a surgical guide is to transfer the implant position planned on the computer as precisely as possible. Accuracy does not depend only on the surgery itself; it is also achieved at the planning stage.
The parameters demonstrated in this study should therefore be considered and applied, as far as possible, from the planning stage onward. Keeping the drilling distance as short as possible is one of the factors to integrate. However, this principle obviously has to be adapted to the clinical conditions encountered.
Lowering the sleeve position relative to the implant platform is one of the decision factors to evaluate in order to reduce drilling distance. However, this must not conflict with other clinical principles that could compromise implant surgery, such as:
a sleeve placed too low that interferes with the surrounding bone and gingiva, preventing the guide from seating correctly;
an inability to irrigate the drilling site, with a risk of overheating the osteotomy.
It is also important to note that every implant system is different, with different sleeve sizes. Simply choosing one system over another can therefore reduce the length of drilling that is actually guided.
The evolution of implant systems must also be considered. A growing number of guided surgery systems are keyless, which reduces the portion of the drill that is truly guided. Other systems offer no option to change the sleeve position, removing another factor that could be adjusted to increase the accuracy of guided surgery. Even so, understanding that free drilling distance has an impact remains essential during planning.
What does this mean for your D2D planning?
At D2D, every case is planned by Dr. Doliveux or Dr. El Kholy, two clinicians with recognized experience in guided surgery. They consider the clinical situation as a whole, at both the anatomical and prosthetic levels, as well as the biomechanical parameters that can influence the outcome of surgery.
An implant plan must integrate all of these factors, weighing the importance of some against others for a given clinical situation. It is not about applying the same recipe repeatedly and uniformly.
D2D offers a planning service built on both theoretical knowledge and surgical reality.
FAQ
Does the vertical position of the sleeve change the accuracy of guided surgery?
Not on its own. The article reports that it is the drilling distance that can produce a significant difference in guided surgery accuracy [1].
Will planning a shorter implant be more accurate?
Implant length alone does not influence the accuracy of guided surgery [1].
Can reducing the free drilling distance reduce the risk of deviation in guided surgery?
Yes. Aiming to reduce the free, and therefore not strictly guided, drilling distance can limit the risk of variation or deviation in guided surgery. Other factors that may also influence accuracy must still be taken into account.
Plan your next guided case with D2D
Create your account at app.d2dplanning.com and request planning for your next guided surgery case. Your case will be planned personally by Dr. Doliveux, with an STL surgical guide delivered in 3–5 business days that you can print in your clinic, or you can request the printed guide to be shipped directly to you.
About the author
Dr. Simon Doliveux is co-founder of D2D Planning. He completed a three-year postdoctoral program in implant dentistry at the Harvard School of Dental Medicine. An ITI Fellow and international speaker, he dedicates his practice exclusively to implant surgery and implant prosthetic rehabilitation.
References
[1] El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 2019;21(1):101–107. doi:10.1111/cid.12705
No technician, no engineer.
Just surgical planning by one dentist for another.

No technician, no engineer.
Just surgical planning by one dentist for another.

No technician, no engineer.
Just surgical planning by one dentist for another.

Oct 2026
6 Mins
Guided Surgery Accuracy: Why Does Free Drilling Distance Matter?
Guided Surgery Accuracy: Why Does Free Drilling Distance Matter?
Guided Surgery Accuracy: Why Does Free Drilling Distance Matter?


Dr. Simon Doliveux
DDS, MMSc
In guided implant surgery, the free drilling distance below the sleeve has a significant effect on implant accuracy. Here is what the research shows and what it means for how your surgical guide is designed.
The accuracy of a surgical guide depends on the anatomical and clinical variations of the implant site, but also on an understanding of the geometric properties of the guide itself.
A key aspect of guided surgery accuracy is the drilling distance between the sleeve and the apical end of the osteotomy. This part of the drilling is called “free”: once the implant drill passes the base of the sleeve, it is no longer guided.
Understanding this distance, and taking it into account during implant planning, changes the way the guide itself is designed.
This is what a study led by Dr. Karim El Kholy, co-founder of D2D, set out to highlight in an article published in Clinical Implant Dentistry and Related Research in 2019 [1].
The impact of free drilling distance
In their in vitro study, Dr. El Kholy et al. looked at three variables of static computer-assisted implant surgery (sCAIS):
Sleeve height: the vertical distance between the base of the sleeve and the bone crest.
Drilling distance: the length the implant drill travels from the base of the sleeve without lateral support (14, 16 and 18 mm).
Drilling key: the height of the key that is inserted into the guide sleeve.

Results
This study shows that some choices made when designing the guide play a role in surgical accuracy, while other parameters do not necessarily have the expected impact.
The article showed that sleeve height alone does not significantly change the 3D position of the implant. Likewise, changing implant length alone does not appear to alter the accuracy of guided surgery.
However, drilling distance does appear to affect the accuracy of guided surgery. For example, an 18 mm drilling distance produced a significant deviation of the implant from its planned position, compared with a 14 mm drilling distance [1].

What the article clearly demonstrated is that the distance over which the implant drill is actually guided has a significant influence on implant deviation. The longer the drill is guided laterally, the more accurate the implant position. In other words, the shorter the drilling distance below the sleeve and the greater the key height, the more the drill is truly guided, and the less deviation occurs. Conversely, the longer the unsupported, or “free”, drilling distance, the greater the risk of deviation.
Impact on guide design
The purpose of a surgical guide is to transfer the implant position planned on the computer as precisely as possible. Accuracy does not depend only on the surgery itself; it is also achieved at the planning stage.
The parameters demonstrated in this study should therefore be considered and applied, as far as possible, from the planning stage onward. Keeping the drilling distance as short as possible is one of the factors to integrate. However, this principle obviously has to be adapted to the clinical conditions encountered.
Lowering the sleeve position relative to the implant platform is one of the decision factors to evaluate in order to reduce drilling distance. However, this must not conflict with other clinical principles that could compromise implant surgery, such as:
a sleeve placed too low that interferes with the surrounding bone and gingiva, preventing the guide from seating correctly;
an inability to irrigate the drilling site, with a risk of overheating the osteotomy.
It is also important to note that every implant system is different, with different sleeve sizes. Simply choosing one system over another can therefore reduce the length of drilling that is actually guided.
The evolution of implant systems must also be considered. A growing number of guided surgery systems are keyless, which reduces the portion of the drill that is truly guided. Other systems offer no option to change the sleeve position, removing another factor that could be adjusted to increase the accuracy of guided surgery. Even so, understanding that free drilling distance has an impact remains essential during planning.
What does this mean for your D2D planning?
At D2D, every case is planned by Dr. Doliveux or Dr. El Kholy, two clinicians with recognized experience in guided surgery. They consider the clinical situation as a whole, at both the anatomical and prosthetic levels, as well as the biomechanical parameters that can influence the outcome of surgery.
An implant plan must integrate all of these factors, weighing the importance of some against others for a given clinical situation. It is not about applying the same recipe repeatedly and uniformly.
D2D offers a planning service built on both theoretical knowledge and surgical reality.
FAQ
Does the vertical position of the sleeve change the accuracy of guided surgery?
Not on its own. The article reports that it is the drilling distance that can produce a significant difference in guided surgery accuracy [1].
Will planning a shorter implant be more accurate?
Implant length alone does not influence the accuracy of guided surgery [1].
Can reducing the free drilling distance reduce the risk of deviation in guided surgery?
Yes. Aiming to reduce the free, and therefore not strictly guided, drilling distance can limit the risk of variation or deviation in guided surgery. Other factors that may also influence accuracy must still be taken into account.
Plan your next guided case with D2D
Create your account at app.d2dplanning.com and request planning for your next guided surgery case. Your case will be planned personally by Dr. Doliveux, with an STL surgical guide delivered in 3–5 business days that you can print in your clinic, or you can request the printed guide to be shipped directly to you.
About the author
Dr. Simon Doliveux is co-founder of D2D Planning. He completed a three-year postdoctoral program in implant dentistry at the Harvard School of Dental Medicine. An ITI Fellow and international speaker, he dedicates his practice exclusively to implant surgery and implant prosthetic rehabilitation.
References
[1] El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 2019;21(1):101–107. doi:10.1111/cid.12705
No technician, no engineer.
Just surgical planning by one dentist for another.

No technician, no engineer.
Just surgical planning by one dentist for another.

No technician, no engineer.
Just surgical planning by one dentist for another.